Temperature Range: Our advanced insulation material operates efficiently across a wide temperature range of -70°C to 1000°C, making it ideal for various industrial applications.

Thermal Conductivity: With a thermal conductivity of less than 0.035 W/(m·K) at normal temperature, our product ensures optimal thermal efficiency, helping to maintain desired temperatures while saving energy.

Material Density: This insulation material boasts a lightweight density of 100-200 kg/m³, allowing for easy handling and installation in any setting.

Thickness: Available in thicknesses ranging from 35mm to 50mm, it provides flexible options to meet your specific insulation needs.

Flame Retardant Performance: Our product is classified as A grade non-flammable, ensuring maximum safety in high-temperature environments.

Anti-Corrosion Properties: Designed to withstand harsh conditions, our material offers exceptional resistance to acids, alkalis, and other corrosive substances, as well as water and oil.

Lifetime: Engineered for durability, this insulation material has a lifespan of more than 10 years, making it a reliable choice for long-term use.

As a leading supplier and factory in China, we are committed to providing top-quality insulation solutions that meet the highest industry standards. Trust us for your insulation needs!

    Basic Info.

    Waterproof Yes Fireproof Yes
    Energy Saving Yes Colour Grey
    Warranty 2 Years Refractoriness 200-450℃
    Diameter 10-50mm Apparent Density 180~210kg/m³
    Usage Exterior Tiles Transport Package Standard Export Carton
    Specification customized Trademark Jiecheng
    Origin China HS Code 7019909000
    Production Capacity 30000/Year

    High-efficiency thermal insulation and energy conservation

    High-efficiency thermal insulation and energy conservation: The insulation jacket can significantly reduce the heat transfer of valves. For valves with high-temperature media, it can effectively prevent heat dissipation, and for valves with low-temperature media, it can prevent cold loss. This reduces energy consumption, improves energy utilization efficiency, and cuts down on operating costs. For example, in a steam pipeline system, after installing the insulation jacket, the heat dissipation of the valves can be reduced by approximately 80%, saving a substantial amount of energy.

    High safety performance

    The materials used for the insulation cover generally have good flame retardancy and high-temperature resistance, which can effectively prevent fire accidents and ensure production safety.
    case
    applicant

    Here are the operating steps for installing the valve insulation jacket:

    1. Prepare the tools and materials:
    Gather the necessary tools, such as scissors, tape measures, and utility knives, as well as the insulation jacket and any accompanying fasteners or sealing materials.
    2. Measure the valve:
    Use a tape measure to accurately measure the dimensions of the valve, including its length, diameter, and any protruding parts. This ensures that the insulation jacket fits properly.
    3. Clean the valve surface:
    Remove any dirt, oil, or rust from the valve surface using a clean cloth or appropriate cleaning agent. A clean surface helps the insulation jacket adhere better and ensures good thermal insulation performance.
    4. Install the insulation jacket:
    1). Unfold the insulation jacket and place it over the valve, aligning it properly. Make sure the jacket covers the entire valve evenly, including the valve body, stem, and any attached fittings.
    2). If the insulation jacket is in multiple pieces, assemble them in the correct order and secure the connections tightly. Use zippers, buckles, straps, or adhesive tapes to fasten the jacket around the valve, ensuring a snug fit.
    3). For some insulation jackets, there may be specific installation instructions for wrapping around complex valve shapes or dealing with protruding parts. Follow these instructions carefully to ensure a proper installation.
    5. Seal the edges and joints:
    Use sealing materials such as silicone sealant or adhesive tape to seal the edges and joints of the insulation jacket. This prevents heat or cold from escaping through the gaps and improves the overall insulation effect.
    6. Check and adjust:
    After installation, carefully check the entire insulation jacket to ensure that it is installed firmly and there are no loose or damaged parts. Check if the valve can still operate smoothly without being affected by the insulation jacket. Make any necessary adjustments to the jacket or fastenings to ensure a perfect fit and normal valve operation.
    7. Mark and label (if necessary):
    If there are specific requirements or regulations, mark or label the insulated valve for identification purposes. This may include information such as the valve type, operating temperature, and maintenance instructions.
    Product-Line-Material
    Product-description1
    Thermal insulation performance comparison
    new material (1)
    Finished-product-display-and-before-and-after-temperature-comparison2

    Frequently Asked Questions

    What is the working temperature range of this insulation jacket?
    The refractoriness range is between 200℃ and 450℃, making it suitable for standard and high-temperature thermal pipe systems.
    How much energy can be saved by using this valve insulation jacket?
    In typical steam pipeline systems, installing the insulation jacket can reduce valve heat dissipation by approximately 80%, substantially cutting energy consumption.
    Is the valve insulation jacket waterproof and fireproof?
    Yes, the jacket is designed with both waterproof and flame-retardant properties to enhance safety and withstand demanding environmental conditions.
    Can the jacket be customized for non-standard valve dimensions?
    Yes, specifications are fully customizable based on measured diameter (10-50mm range and custom requirements), valve shape, and complex pipeline structures.
    What is the warranty period for this product?
    The product comes with a standard 2-year warranty under normal operating and installation conditions.
    Will installing this insulation jacket affect normal valve operation?
    No. When correctly fitted and fastened using the provided straps, buckles, or zippers, the jacket allows the valve stem and moving parts to operate smoothly.